Stainless Steel Pipe and Tube Standards Compared: ASTM A312, A269, A249, A213, A554, A270, A790, A358, A688 and A778

Stainless steel seamless pipe

·

By Yuhang Metal Technical Team · Updated November 2026 · 8 min read

Short answer: Use ASTM A312 for stainless process pipe, A269 for general-service tubing, A213 (seamless) or A249 (welded) for heat-exchanger tubes, A688 for feedwater heater U-tubes, A270 for sanitary tubing, A554 for mechanical and decorative tubing, and A790 for duplex pipe. Pipe is ordered by NPS and schedule; tube by actual OD × wall.

Ordering stainless steel pipe or tube to the wrong specification is one of the most common reasons for rejected shipments. The standard is not only a quality label. It defines whether the product is seamless or welded, how it is heat treated, which tests are carried out on every length, the dimensional tolerances, and the service it is intended for. This guide compares the ASTM specifications buyers meet most often, and shows how to pick the right one.

Key takeaways

  • Pipe (A312, A358, A778, A790) is ordered by nominal pipe size (NPS) and schedule. Tube (A269, A249, A213, A688, A270, A554) is ordered by actual outside diameter × wall thickness.
  • A312 is the general specification for stainless pressure pipe. A358 covers electric-fusion-welded pipe made from plate, usually in large diameters. A778 covers unannealed welded pipe for low- to moderate-temperature corrosive service.
  • A213 (seamless) and A249 (welded) cover boiler, superheater and heat-exchanger tubes. A688 covers feedwater heater tubes, including U-bends.
  • A269 is general-service tubing, A270 sanitary tubing and A554 mechanical tubing for structural and decorative use.
  • A790 (pipe) and A789 (tube) are the duplex stainless steel specifications.

Pipe or tube: why the difference matters

Pipe is designated by NPS and schedule. For stainless steel the dimensions follow ASME B36.19M with schedules such as 5S, 10S, 40S and 80S. The outside diameter is fixed for each NPS, for example NPS 2 = 60.3 mm OD, and the schedule sets the wall. Pipe specifications such as A312 and A790 call up the general requirements of ASTM A999.

Tube is ordered by its actual OD and wall thickness, usually with tighter tolerances. It is used for heat exchangers, instruments, hygienic lines and mechanical parts. Heat-exchanger and general-service tube specifications such as A213, A249, A269 and A688 call up the general requirements of ASTM A1016.

ASTM stainless steel pipe and tube standards compared

StandardScopeSeamless / weldedTypical useNotes
ASTM A312/A312MSeamless, welded and heavily cold-worked austenitic stainless steel pipeBothProcess piping for high-temperature and general corrosive serviceSupplied heat treated. Each length is hydrostatically tested or examined by a non-destructive electric test
ASTM A358/A358MElectric-fusion-welded (EFW) austenitic chromium-nickel stainless steel pipe for high-temperature service and general applicationsWelded (formed from plate)Large-diameter process and transfer pipingFive classes differ in single or double welding, filler metal and the extent of radiography
ASTM A778/A778MWelded, unannealed austenitic stainless steel tubular productsWelded, not annealedLow- and moderate-temperature corrosive service, such as water treatment, pulp and paper, and ductingCovers 3–48 in (75–1200 mm) OD in L-grades and stabilized grades. Where post-weld heat treatment or radiography is required, the standard refers buyers to A312, A358 or A409
ASTM A790/A790MSeamless and welded ferritic/austenitic (duplex) stainless steel pipeBothChloride-bearing process lines, offshore, desalinationGrades such as 2205 (S31803/S32205) and 2507 (S32750). The tubing equivalent is A789
ASTM A269/A269MSeamless and welded austenitic stainless steel tubing for general serviceBothInstrumentation, hydraulic and general corrosion-resistant tubingThe most widely used general-purpose tubing specification
ASTM A249/A249MWelded austenitic steel boiler, superheater, heat-exchanger and condenser tubesWeldedShell-and-tube heat exchangers, condensersAnnealed tube with flattening, flange and reverse-bend tests on the weld
ASTM A213/A213MSeamless ferritic and austenitic alloy-steel boiler, superheater and heat-exchanger tubesSeamlessBoilers, superheaters, high-pressure heat exchangersAlso covers ferritic alloy grades such as T11, T22 and T91 alongside TP304, TP316, TP321 and others
ASTM A688/A688MSeamless and welded austenitic stainless steel feedwater heater tubes, including U-bent tubes when specifiedBothPower-plant feedwater heaters, U-tube exchangersSets U-bend tolerances for ovality, wall thinning, leg length and leg spacing. See our U-bend tube guide
ASTM A270/A270MSeamless and welded austenitic and ferritic/austenitic stainless steel sanitary tubingBothDairy, food, beverage and pharmaceutical linesPolished inside and outside surfaces. Supplementary requirement S2 covers pharmaceutical-quality tubing. ASME BPE is often specified alongside it
ASTM A554Welded stainless steel mechanical tubingWeldedHandrails, furniture, automotive, structural and decorative partsRound, square, rectangular and special shapes, intended for mechanical rather than pressure duty
Stainless steel welded pipes

Welded Pipes
ASTM A312 / A358 / A778, NPS 1/8″–30″

Stainless steel seamless pipes

Seamless Pipes
ASTM A312 / A213 / A269 / A790

Stainless steel sanitary tubes

Sanitary Tubes
Polished tubing for hygienic lines

Stainless steel u-bend tubes

U-Bend Tubes
A213 / A249 / A688, legs up to 15 m

How to choose the right specification

  • Plant piping under pressure: welded or seamless pipe to A312. For large diameters made from plate, A358.
  • Large-diameter, low-pressure corrosive service where annealing is not needed: A778.
  • Chloride environments, or where higher strength is needed: duplex pipe to A790, or tube to A789.
  • Heat-exchanger and condenser tubes: A213 for seamless, A249 for welded. For feedwater heaters and U-bundles, A688. See U-bend tubes.
  • Instrumentation, hydraulic and general tubing: A269. See precision and instrumentation tubes and round tubes.
  • Hygienic process lines: sanitary tubes to A270, plus ASME BPE for pharmaceutical systems.
  • Structural, architectural and decorative parts: mechanical tubes to A554.

EN and GB counterparts

Projects in Europe and China often quote EN or GB standards. The documents below are the nearest counterparts, not direct substitutes. Always compare the dimensions, tolerances and test requirements before accepting one in place of another.

ProductASTMENGB
Seamless pressure pipe and tubeA312, A213, A269EN 10216-5GB/T 14976 (fluid), GB/T 13296 (boiler and heat exchanger)
Welded pressure pipe and tubeA312, A358, A249, A269EN 10217-7GB/T 12771 (fluid)
Welded mechanical and structural tubeA554EN 10296-2GB/T 12770
Welded tube for food and chemical industryA270EN 10357—

Dual certification and ASME SA specifications

Austenitic pipe and tube is often dual-certified, for example 304/304L or 316/316L. Dual certification means the material meets the low-carbon limit of the L grade (0.030% C maximum) and the strength requirements of the standard grade. For work under the ASME Boiler and Pressure Vessel Code, material must be certified to the ASME version of the specification (SA-312, SA-213, SA-249, SA-688 and so on). These are adopted from the ASTM editions and are usually identical in content.

What to put on your pipe or tube order

  1. Specification and edition year, for example ASTM A312/A312M-24
  2. Grade and UNS number, for example TP316L / S31603
  3. Seamless or welded
  4. Size: NPS and schedule for pipe, or OD × wall (minimum or average) for tube
  5. Length: random, fixed or cut-to-length, with tolerance
  6. End finish (plain, beveled, threaded) and surface (pickled, bright annealed, polished)
  7. Tests: hydrostatic or eddy current, plus any extras such as ultrasonic, PMI or intergranular corrosion testing to ASTM A262 Practice E
  8. Certificates to EN 10204 3.1 or 3.2, with marking and packing requirements

See our full range of stainless steel pipes and tubes, or send us your specification for a quotation.

Why source from Yuhang Metal

  • Stainless steel supplier based in Foshan, Guangdong, since 1986. In 1988 we commissioned China’s first stainless steel high-frequency welded pipe mill.
  • Welded pipe from NPS 1/8″ to 30″ to ASTM A312, A358 and A778, and seamless pipe and tube to A312, A213, A269 and A790.
  • Hydrostatic and eddy current testing, with further tests such as ultrasonic, weld X-ray, PMI or intergranular corrosion testing available.
  • EN 10204 3.1 or 3.2 certificates.

Frequently asked questions

What is the difference between ASTM A312 and ASTM A269?

ASTM A312 covers stainless steel pipe ordered by nominal pipe size and schedule for high-temperature and general corrosive service. ASTM A269 covers stainless steel tubing for general service, ordered by actual outside diameter and wall thickness. A312 is used for process piping. A269 is used for instrumentation, hydraulic and general tubing.

What is the difference between ASTM A213 and ASTM A249?

Both cover boiler, superheater and heat-exchanger tubes. A213 is for seamless tubes, including ferritic alloy grades such as T11, T22 and T91. A249 is for welded austenitic tubes.

Can ASTM A554 tubing be used for pressure applications?

A554 is a mechanical tubing specification intended for structural, architectural and decorative uses. For pressure duty, specify a pressure-rated specification such as A269, A249 or A312.

What does dual-certified 304/304L mean?

The material meets the chemistry of 304L, with 0.030% carbon maximum, and the mechanical properties of 304. It can therefore be supplied against orders for either grade.

Is ASTM A312 the same as ASME SA-312?

SA-312 is the ASME Boiler and Pressure Vessel Code adoption of ASTM A312 and is usually identical in content. Work under the ASME Code requires material certified to the SA specification.

Which ASTM standard should I use for heat exchanger tubes?

Use ASTM A213 for seamless tubes and ASTM A249 for welded tubes. For feedwater heaters and U-tube bundles, ASTM A688 adds U-bend tolerances. For duplex grades, use ASTM A789.

What is the difference between ASTM A269 and ASTM A270?

A269 covers stainless steel tubing for general corrosion-resistant and low- or high-temperature service. A270 covers sanitary tubing for the dairy, food and pharmaceutical industries, with polished inside and outside surfaces and an optional pharmaceutical-quality supplementary requirement.

What tests are carried out on stainless steel pipe?

Pipe specifications such as A312 require every length to be hydrostatically tested or examined by a non-destructive electric test such as eddy current, plus mechanical tests such as flattening. Extra tests, for example ultrasonic examination, PMI or intergranular corrosion testing to ASTM A262 Practice E, are added on the purchase order.

References

  • ASTM A312/A312M, A358/A358M, A778/A778M, A790/A790M, A789/A789M
  • ASTM A269/A269M, A249/A249M, A213/A213M, A688/A688M, A270/A270M, A554
  • ASTM A999/A999M and A1016/A1016M (general requirements)
  • ASME B36.19M (stainless steel pipe dimensions)
  • EN 10216-5, EN 10217-7, EN 10296-2, EN 10357; GB/T 14976, GB/T 12771, GB/T 12770, GB/T 13296

Need a quotation or technical advice?

Send your drawing, specification or questions to our engineering team. We usually reply within one working day.